Products
|
||||
![]() |
|||||||
|
|
![]() |
Two different battery options are available:- |
Highlights |
|
Data Logging – Records time and temperature data for later download |
|
Day alarm summary - Displays in calendar-like format alarm triggers for up to the last 30days |
|
Current time & temperature - Shows the current time and temperature when not in review mode |
|
Push Button Logging start with optional delayed start or specific Time & Date start |
|
Rapid Download! Takes only seconds to download recordings |
|
‘Pre-Start’ logging - Logtag can be configured to record even if it has not been started. |
|
High performance at low cost |
|
Thin flat case – Fits easily into packaging and thin enough to be easily mailed “letter rate”. |
|
Real time clock records time & temperature simultaneously |
|
Easy to use LogTag Analyzer software that runs on any PC configures LogTag for recording then downloads resulting data for analysis.
Data can also be exported to fomats compatible with other applications such as Excel |
|
Re-calibration to achieve higher accuracy possible |
|
High quality gold plated remote sensor connector |
|
Interchangeable Remote Probes – LogTag remote temperature probes are interchangeable provided they are changed with LogTag ST100 type remote temperature sensors. |
|
Product Brochure |
||
QuickStart Guide |
Product Specification & Guide |
Remote Probe Option (type ST100)
|
||
![]() Part#s ST100S-15 (1.5m) or ST100S-30 (3m) |
|
|
Part#s ST100T-15 (1.5m) and ST100T-30 (3.0m) |
|
|
|
||
![]() Part#s ST100H-15 (1.5m) and ST100H-30 (3.0m) |
|
|
Parts# ST100B-15 (1.5m) and ST100B-30 (3.0m) |
|
|
Specifications |
||
Model#s |
TRED30-7R : (replaceable battery) TRED30-7F : (fixed battery) |
|
Remote Sensor measurement Range |
-40°C
~ +99°C (-40°F ~ +210°F) |
|
Recorder operating temperature range
|
-30°C
~ +60°C (-22°F ~ +140°F) |
|
Rated Temperature reading accuracy |
Better than ±0.5°C (±0.9°F) for -20°C~+40°C (-22°F~+104°F) -typically ±0.3°C (0.6°F) Better than ±0.8°C (±1.5°F) for -40°C~+20°C (-40°F~ -22°F) - typically ±0.5°C (0.9°F) Better than ±0.8°C (±1.5°F) for +40°C~+70°C (-104°F~+158°F) - typically ±0.7°C (0.9°F) Better than ±1.2°C (±1.5°F) for +70°C~+99°C (-158°F~+210°F) - typically ±1°C (0.9°F). |
|
Sensor
reaction time (T90) |
T90 typically
less than 2 minutes in moving air (1m/s) for ST100T,ST100H & ST100S types. |
|
Display Resolution |
0.1°C(0.2°F) for measurements -40°C ~ +50°C (-22°F ~ +122°F) 0.2°C(0.4°F) for measurements +50°C ~ +70°C (+122°F ~ +158°F) 0.3°C(0.5°F) for measurements +70°C ~ +80°C (+158°F ~ +176°F) 0.4°C-0.6°C(0.7°F~1°F) for measurements +80°C~ +99°C (+176°F ~ +210°F) |
|
Capacity |
Data logging memory : 7770 logs ( 53 days @ 10min logging, 80 days @ 15min logging) Day summary statistics memory (for display on LCD): up for 30 days of Max/Min and duration values |
|
Sampling
frequency |
adjustable,
30 seconds to several hours |
|
Logging start options |
Push button start or specific date & time. Optional start delay of up to 18hours. |
|
Recording
indication |
State indicator "RECORDING" |
|
Download
Time |
Typically
with full memory (7770 readings) in less than 5 secs depending on computer
or readout device used. |
|
Environmental |
IP61 |
|
Power
source |
3V Lithium-Manganese Dioxide extended temperature chemistry |
|
Battery
life |
TRED30-7R : typically 1 year of operation TRED30-7F : typically 2+ years of operation |
|
Size |
93.0mm(H)x54.5mm(W)x8.6mm(T) |
|
Weight |
TRED30-7R : 41grams TRED30-7F : 44 grams |
|
Case
Material |
Polycarbonate |
|
Reader interface |
Standard LogTag Interface cradle |
|
Remote Temperature probes |
Standard LogTag® ST100 temperature probes (Standard lengths 1.5m (4’11”) or 3m (9’10”)) |
|
Other
features |
|
Optional
clearing of alarm indication by push button (places inspection mark at same
time). |
Note: Resolution &
Accuracy are rated values - actual product performance may be substantially
better than figures stated. |
||
Standards compliance |
||
EMC
Compliance |
Tested and complies
with EC EMC directives (EN 61000-6-3:2006 & EN 61000-6-1:2005) Tested and complies
FCC Part 15 Subparts A and B as an unintentional radiator.. |
|
FDA CFR21 Part 11 Compliance |
Designed
for FDA CFR21 Part 11 Digital signatures |
|
Manufactured to meet the European RoHS Directive The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants. |
||
Accessories |
||
![]() |
|
|
![]() |
|
|