Products
|
||||
![]() |
|||||||
LogTag Dry-Ice probe-less low temperature Recorder |
|
![]() |
|
Readings are downloaded using LogTag Analyzer, which provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel. |
|
Highlights |
|
Alert indicator – indicates if readings are outside of preset limits |
|
OK indicator indicates if still recording and if readings within configured limits |
|
Inspection mark in log by push button |
|
Push Button Logging start with optional delayed start or specific Time & Date start |
|
Rapid Download! Takes only seconds to download recordings |
|
‘Pre-Start’ logging - Logtag can be configured to record even if it has not been started. |
|
High performance at low cost |
|
Credit card sized case – thin enough to be easily mailed “letter rate”. |
|
Real time clock records time & temperature simultaneously |
|
Easy to use LogTag Analyzer software that runs on any PC configures LogTag for recording then downloads resulting data for analysis.
Data can also be exported to fomats compatible with other applications such as MS Excel |
|
Re-calibration to achieve higher accuracy possible |
|
Product data sheet |
||
Quick Start Guide |
Specifications |
||
Model# |
TRIL-8 (Multi-use : 3 trips) |
|
Measurement Range |
-80 ~ +40°C (-112°F ~ +104°F) |
|
Resolution |
< 0.1°C for -80°C ~ 0.0°C, |
|
Accuracy |
Better than ±1°C for -30°C~ +20°C |
|
Sensor
reaction time |
typically
less than 5 minutes(T90) in moving air (1m/s). |
|
Capacity |
8000 temperature readings (16Kbytes memory) |
|
Sampling
frequency |
adjustable, 1~60 minutes or 1~18 hours |
|
Logging start options |
Push button start or specific date & time. |
|
Recording
indication |
Flashing
'OK' indicator flashing 'Alert' indicator. |
|
Download
Time |
Typically
with full memory (8000 readings) in less than 5 secs depending on computer
or readout device used. |
|
Environmental |
IP65 (roughly equivalent to NEMA 4) |
|
Power
source |
3V low temperature chemistry Lithium battery. |
|
Battery
life |
Minimum storage life of 12 months before ‘start’. |
|
Size |
86mm(H)x54.5mm(W)x8.6mm(T) |
|
Weight |
35g |
|
Case
Material |
Polycarbonate |
|
Other
features |
|
Optional
clearing of alert indication by push button (places inspection make at same
time). |
Note: Resolution &
Accuracy are rated values - actual product performance may be substantially
better than figures stated. |
||
Standards compliance |
||
EMC
Compliance |
Tested and complies
with EC EMC directives (EN 50081-1:1992 & EN 61000-6-1:2001) Tested and complies
FCC Part 15 Subparts A and B. |
|
FDA CFR21 Part 11 Compliance |
Designed
for FDA CFR21 Part 11 Digital signatures |
|
Manufactured to meet the European RoHS Directive The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants. |
||