Vaxtag® - WHO PQS listed for vaccines

Key Features:
Key Feature Key Benefit Key Benefit Key Benefit

Display shows the current time & temperature plus alarm status


30 day statistics summary reviewable on device display


WHO PQS Pre-qualified under E006 devices : PQS Code E006/013


Pre-configured parameters to match WHO requirements

The LogTag® Vaxtag® is intended for use as the principal means for monitoring storage conditions in vaccine refrigerators in intermediate stores and health facilities. It is delivered to you configured and packaged in compliance with the World Health Organisation (WHO) PQS specification E006/013.


The recorder is configured to suspend processing of readings for alarms and max/min statistics for a period of time after button press activity. This allows the user to review the current statistics or clear an alarm without causing a false alarm or statistic while handling the recorder.


Optional download with LogTag® Analyzer provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel.

'Pause Mark' feature to prevent falsified statistics data from inspection.

Complies with industry standards. Click the 'Specification' tab to view a list of compliance standards.

Models TRID30-7FW (fixed battery, preconfigured and package to meet WHO specification)
Measurement Range -30°C ~ +60°C  (-22°F ~ +140°F)
Resolution 0.1°C (0.2°F) for measurements -30°C ~ +40°C (-22°F ~ +104°F)
0.2°C (0.4°F) for measurements above +40°C (+104°F)
Accuracy Better than ±0.5°C (±0.9°F) for measurements from -20°C~+40°C (-4°F~+104°F) -typically ±0.3°C (0.6°F)
Better than ±0.8°C (±1.5°F) for other measurements - typically ±0.5°C (0.9°F)
Sensor Reaction Time Typically less than 5 minutes(T90) in moving air (1m/s)
Capacity Data logging memory : 7770 logs ( 32 days @ 6min logging )
Day summary statistics memory (for display on LCD): up for 30 days of Max/Min and duration values
Sampling Frequency Factory set to 6 minute interval
Logging Start Options Factory set to Push button start
Recording Indication State indicator "RECORDING"
Download Time Typically with full memory (7770 readings) in less than 5 seconds depending on computer or readout device used.
Environmental IP65 (roughly equivalent to NEMA 4) when vertically mounted or hung
Power Source 3V Lithium-Manganese Dioxide extended temperature chemistry
Alarm Triggering Low alarm : Exposure to a single temperature event of -0.5°C or below for 60 minutes
High alarm: Exposure to a single temperature event of +8°C or above for 10 hours
Battery Life Typically 2+ years of operation. This assumes day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time.
Size 93mm(H)x54.5mm(W)x8.6mm(T)
Weight 43g
Case Material Polycarbonate
Remote Temperature Probes Standard LogTag® ST100 temperature probes (Standard lengths 1.5m (4’11”) or 3m (9’10”))
Other Features • Download inspection mark recorded in LogTag memory every time LogTag is downloaded.
• Low battery indication.
• Compatible with standard LogTag Interface cradle

EMC Compliance
EMC Compliance

Tested and complies with EC EMC directives (EN 50081-1:1992 & EN 61000-6-1:2001) Vaxtag® CE mark EMC declaration of conformance

Tested and complies FCC Part 15 Subparts A and B. ® Vaxtag® FCC EMC declaration of conformance

WHO Compliance
WHO Compliance

WHO PQS Pre-qualified under E006 devices : PQS Code E006/013

See WHO PQS pre-qualification letter
Listed on the WHO website Click here to view

FDA CFR21 Part 11 Compliance
FDA CFR21 Part 11 Compliance

Designed for FDA CFR21 Part 11 Digital signatures

RoHS Compliance
RoHS Directive

The RoHS Directive stands for "the restriction of the use of certain hazardous substances in electrical and electronic equipment". This Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants.

Interface Cradle
Interface Cradle

LogTags® unique interface cradle design provides rapid and reliable data transfer to LogTag® Analyzer software in a matter of seconds. By far the fastest in its class.

Click here for Interface Cradle details
Protective Enclosure
Protective Enclosure

The LogTag® Protective Enclosure is specifically designed for use with LogTag® recorder products and allows LogTags® to be used in harsh environments.

Click here for Protective Enclosure details
Wall Mount Bracket
Wall Mount Bracket

The LogTag® Wall Mount Bracket provides an easy and tidy solution to mounting a LogTag® on a wall, door or vertical surface while still allowing easy removal of the LogTag for inspection or download.

Click here for Wall Mount Bracket details
support
Product Brochure

View product highlights & full specifications as a downloadable PDF


Click here to download the Product Brochure
Quick Start Guide
Vaxtag® Quickstart Guide

Learn how to quickly operate the Vaxtag® device following the step-by-step instructions.


Click here download the Vaxtag® Quickstart Guide
support
Product User Guide

View the LogTag User Guide to learn about all the available features & how to operate the LogTag device.


Click here to download the Product User Guide
support
FAQ/Troubleshooting

Get answers to your questions 24/7 by visiting our resource and support section.


Click here to view the support area
Software
LogTag® Analyzer Software

Get access to our free software which you can use with the Vaxtag® device.


Click here to download the latest version of LogTag Analyzer